Intensive Care Ventilator KVI- A102 is designed to meet the needs of clinical respiratory management for Infants with respiratory disorder. It has a provision to work with innovative ventilation modes like constant flow, pressure limit and time cycle ventilation.
Tidal Volume | 10 ml ~ 300 ml |
Standard Ventilation Mode | CMV, IMV, CPAP, Manual |
Application | Pediatric |
Inspiratory Flow | 3 L/min ~ 20 L/min |
Respiration rate | 1 bpm ~120 bpm |
I:E Ratio | 1:1 to 1:3 |
Oxygen Concentration | 21 % ~ 100 % |
Pressure trigger Range | -1.0 to 0 kPa |
Flow Trigger Range | 0 to 10 L |
PEEP Type | Pneumatic Driven, Electronic Control |
Inspiratory Pause Time | 0.2 s ~ 3.0 s |
Maximum Security Pressure | ≤ 10 kPa |
PEEP Range | 0 kPa ~2.0 kPa |
Max Ventilation Volume | > 5 L/min |
Input Pressure | 0.15 MPa ~ 0.3 Mpa |
Inspiratory Pressure | 1 kPa ~ 9 kPa |
Innovative ventilation mode Safe and Reliable Compact and Reasonable
Used in operating rooms, NICU, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.
Infant Incubator is used in neonatal care to regulate temperature and humidity conditions inorder to maintain a controlled environment for neonates. Acmed Equipment Infant Incubator range features accurate temperature and humidity monitoring and regulation, accessible outer shell with easy-to-clean surfaces, spacious adjustable baby bed.
Infant Warmer is an essential equipment in neonatal care to regulate radiant temperature, often used in maternity wards for newborn babies to provide them with controlled weaning temperature according to medicals standards and practice. Acmed Equipment Infant Warmer range provides a wide range with bed tilt, sensor-based temperature control, alarms and other user-oriented features for effective clinical workflow.
Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.
Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.
Acmed Equipment offers a wide range of superior quality portable and mini-sized Infusion pumps, suited for a wide range of applications in hospitals wards and clinics. Infusion pumps are medical devices capable of delivering a controlled dosage of fluidized drugs, enteral nutrition into a patient's circulatory system.
Acmed Equipment offers a wide selection for Syringe Pump. Our Syringe pump systems are programmed with memory based on safety limits of drugs to deliver intermittent infusion for a specific duration according to associated safety and performance standards.
Acmed Equipment offers a wide selection for Blood or Infusion warmer. Our infusion warmers are designed for leak-proof optimized warming with self-monitored temperature test and alarms as per associated safety and performance standards.