Defibrillator Monitor KDM-A100 is a biphasic life-support clinical defibrillator equipped with provisional core functionalities which include guided automatic as well as manual defibrillation modes, advanced ECG monitoring, SpO2 monitoring and analysis for predictive arrhythmia detection as well as thermal recorder. System features high resolution screen, touch-key panel to display and select various monitoring parameters with energy navigation knob and alarm.

20 Reviews
Display 7-inch screen
Waveform Biphasic
Manual with Sync mode 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
AED mode Auto analyze and charge x 3 with programmable auto energy level selection.
Interpreted rhythms for AED Ventricular fibrillation ≥ 200 µV
Ventricular tachycardia ≥ 140 bpm
QRS complex wave duration ≥ 140 ms
Sweep Speed 25 mm/s
Electrode impedance range 0 Ω – 250 Ω
Analysis Time Less than 7 seconds
ECG Lead selection Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V
ECG Heart rate 20 bpm – 300 bpm
ECG size 0.25, 0.5, 1, 1.5, 2, 4 cm/mV
ECG Heart Rate alarm On / Off displayed on monitor, user-selectable
SpO2measurement 30 % – 100 %
Recorder Paper Speed 12.5 mm/s, 25 mm/s, 50 mm/s
Alarm accuracy ±10 % (less than 12 sec)
Print modes Manual or automatic, user-configurable
Battery Rechargeable, Ni-MH battery, 12V
Dimensions 500 x 380 x 360 mm
Weight 8 Kgs

7-inch high resolution display
AED as well as Manual defibrillation mode
Arrhythmia analysis and recording
Display parameters: Heart Rate, Lead/Pads, Audio/Mute, SpO2 level, Defibrillation energy, Alarm limits

Used in hospital emergency wards, OT, crash-cart throughout the hospital premises, primary healthcare centers and rescue ambulance to deliver counter-shocks during sudden cardiac arrest or cardiac resuscitation situations.

Buy Now: Defibrillator Monitor KDM-A100

Related To Defibrillator

Automated External Defibrillator KED-A100

Infant Incubator

Infant Incubator is used in neonatal care to regulate temperature and humidity conditions inorder to maintain a controlled environment for neonates. Acmed Equipment Infant Incubator range features accurate temperature and humidity monitoring and regulation, accessible outer shell with easy-to-clean surfaces, spacious adjustable baby bed.

Infant Incubator KII-A101

Infant Incubator KII-A101

Control System : Air-temp control & Skin-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A100

Infant Incubator KII-A100

Control System : Air-temp control, Skin-temp control & Humidity control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A102
Infant Incubator KII-A102

Control System : Air-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C

Infant Warmer

Infant Warmer is an essential equipment in neonatal care to regulate radiant temperature, often used in maternity wards for newborn babies to provide them with controlled weaning temperature according to medicals standards and practice. Acmed Equipment Infant Warmer range provides a wide range with bed tilt, sensor-based temperature control, alarms and other user-oriented features for effective clinical workflow.

Infant Warmer KIW-A100
Infant Warmer KIW-A100

Control System : Microprocessor based temperature control system

Control Modes : Preheat, Manual and Skin-temp mode

Manual : Heater output : 0-100%, 10% increments

Phototherapy Unit

Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.

LED Phototherapy System KPT-A100

LED Phototherapy System KPT-A100

Light Source : 8 Blue LED lights

Wavelength : 450 to 475nm

LED Lamp-life : 1,00,000 hours

Infusion Pump

Acmed Equipment offers a wide range of superior quality portable and mini-sized Infusion pumps, suited for a wide range of applications in hospitals wards and clinics. Infusion pumps are medical devices capable of delivering a controlled dosage of fluidized drugs, enteral nutrition into a patient's circulatory system.

Infusion Pump KIP–A100

Infusion Pump KIP–A100

Channel : Single channel infusion

Volume (VTBI) : 1 ml ~ 9999.9 ml ( 0.1 ml increment)

Accuracy : Flow rate: ≤ ± 3 % </br> Mechanical: ≤ ± 2 %

Infusion Pump KIP–A101
Infusion Pump KIP–A101

Channel : Single channel infusion

Infusion Volume : 0 ml ~ 9999 ml ( 0.1ml increment)

Infusion Rate : 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)

Ventilator

Acmed Equipment presents a wide range of pneumatically driven and electronically controlled ventilators that assist the breathing of adults and paediatric patients alike. Acmed Equipment Ventilators feature configurable loops and trends, invasive and non-invasive ventilation, adult and paediatric ventilation, high-flow oxygen therapy. They are applicable in hospitals, clinics, private practices and ambulances.

Intensive Care Ventilator KIV-A101
Intensive Care Ventilator KIV-A101

Tidal Volume : 20 ml ~ 500 ml

Standard Ventilation Mode : VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH

Application : Adult/ Pediatric Invasive

Intensive Care Ventilator KIV-A102

Intensive Care Ventilator KIV-A102

Tidal Volume : 10 ml ~ 300 ml

Standard Ventilation Mode : CMV, IMV, CPAP, Manual

Application : Pediatric

Intensive-Care Ventilator KIV-A200

Intensive-Care Ventilator KIV-A200

Tidal Volume : 20 ml ─ 2500 ml

Configurations : Trolley or Ceiling Pendant

Respiratory Rate : 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) </br> 4 bpm ─ 100 bpm ( VCV/PCV/PRVC)

Transport Ventilator KTV-A100
Transport Ventilator KTV-A100

Tidal Volume : 0 ml – 1500 ml

Gas Supply : O<sub>2</sub>, 0.28 to 0.6 MPa

Ventilation Modes : A/C, SIMV, SPONT, Manual, VCV+SIGH

Syringe Pump

Acmed Equipment offers a wide selection for Syringe Pump. Our Syringe pump systems are programmed with memory based on safety limits of drugs to deliver intermittent infusion for a specific duration according to associated safety and performance standards.

Syringe pump KSP–A200
Syringe pump KSP–A200

Channel : Single channel infusion

Volume (VTBI) : 0 ml – 9999 ml

Injection Compliance : Adaptable for 6 syringe sizes

Syringe pump KSP–B100

Syringe pump KSP–B100

Channel : Dual channel infusion

Volume (VTBI) : 0.1 ml – 1999.9 ml

Injection Compliance : Adaptable for 10 syringe sizes

Syringe pump KSP-A100

Syringe pump KSP-A100

KVO Rate : 0.1 – 5ml/h (steps : 0.1ml/h)

Injection Compliance : Adaptable for 5 syringe sizes

Preset Volume Range : 0.1 ml – 1999.9 ml

Blood and Infusion Warmer

Acmed Equipment offers a wide selection for Blood or Infusion warmer. Our infusion warmers are designed for leak-proof optimized warming with self-monitored temperature test and alarms as per associated safety and performance standards.

Blood and Infusion Warmer KBIW-A100
Blood and Infusion Warmer KBIW-A100

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 0.5°C

Warm-up Time : < 45 s (20°C to 36°C)

Blood and Infusion Warmer KBIW-A200
Blood and Infusion Warmer KBIW-A200

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 1.0°C

Warm-up Time : < 45 s (20°C to 36°C)

Resuscitator

Resuscitator KRE-A101

Resuscitator KRE-A101

Type : Pediatric

Stroke volume : 350 ml

Resuscitator volume : 680 ml

Resuscitator KRE-A102

Resuscitator KRE-A102

Type : Neonatal

Stroke volume : 150 ml

Resuscitator volume : 250 ml

Resuscitator KRE-A100
Resuscitator KRE-A100

Type : Adult

Stroke volume : 800 ml