Infusion Pump KIP–A100

Infusion Pump KIP–A100 is a single-channel light–weight, drip-type volumetric fluid delivery system. Digitally driven fluid-control, automated calibration and dose titration enhances safety. Peristaltic pumping mechanism ensures precise flow-measurement and prevents back-flow of IV fluid. Backlit display enables suitably ambient illumination to operate even at low light condition.

24 Reviews
Channel Single channel infusion
Volume (VTBI) 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Accuracy Flow rate: ≤ ± 3 %
Mechanical: ≤ ± 2 %
KVO Rate 1 ml/h (1 ml/h ~ 300 ml/h)
3 ml/h (greater than 300 ml/h)
Occlusion System 3 selectable occlusion levels
Drop Rate 1 drop/min ~ 400 drops/min (1 drop/min increment)
Infusion Rate 1.0 ml/h ~99.9 ml/h (0.1 ml/h increment)
100 ml/h ~1200 ml/h (1 ml/h increment)
Purge 800 ml/h
Bolus 10 ml/h ~ 1200 ml/h at 0.1 ml/h (flow rate < 100 ml/h)
10 ml/h ~ 1200 ml/h at 1 ml/h (flow rate > 100 ml/h)
Therapy Timer Range 1 min ~ 9999 min ( 1 min increment)
Display 4.3-inch colour LCD with backlight
Drug Library Database of up to 210 drugs
Memory Up to 1500 record entries
Occlusion Threshold High: 800 mmHg ± 200 mmHg (106.7 kPa ± 26.7 kPa)
Medium: 500 mmHg ± 100 mmHg (66.7 kPa ± 13.3 kPa)
Low: 300 mmHg ± 100 mmHg (40.7 kPa ± 13.3 kPa)
Sensitivity [Bubble detection] > 25 μL
Environmental Condition : Operation Operating temperature 5 ⁰C ~ 40 ⁰C
Operating humidity 20 % ~ 90 %
Environmental Condition: Storage Storage temperature -10 ⁰C ~ 55 ⁰C
Storage humidity 10 % ~ 90 %
Fuse F1AL / 250 V
Power Supply AC 85 ~ 265 V, 50/60 Hz, < 40 VA
Battery 11.1 V rechargeable Li-ion battery; > 2000 mAh
Works more than 4 hours at 25 ml/h after charging for 8 hours
Dimensions 188 x 198 x 228 mm
Weight 2.5 Kgs

Infusion Modes - Rate mode, Time mode, Volume mode
Automated calibration
Provision for infusion fluid warming
Built-in drug database library
Suitable for all brands of IV set
Alarm: Infusion Complete, Occlusion, Door Open, Air Bubble,
Low Battery, Setting Error, Power failure, Stand-by

Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.

Buy Now: Infusion Pump KIP–A100

Related To Infusion Pump

Infusion Pump KIP–A101

Infant Incubator

Infant Incubator is used in neonatal care to regulate temperature and humidity conditions inorder to maintain a controlled environment for neonates. Acmed Equipment Infant Incubator range features accurate temperature and humidity monitoring and regulation, accessible outer shell with easy-to-clean surfaces, spacious adjustable baby bed.

Infant Incubator KII-A101

Infant Incubator KII-A101

Control System : Air-temp control & Skin-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A102

Infant Incubator KII-A102

Control System : Air-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C

Infant Incubator KII-A100
Infant Incubator KII-A100

Control System : Air-temp control, Skin-temp control & Humidity control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Warmer

Infant Warmer is an essential equipment in neonatal care to regulate radiant temperature, often used in maternity wards for newborn babies to provide them with controlled weaning temperature according to medicals standards and practice. Acmed Equipment Infant Warmer range provides a wide range with bed tilt, sensor-based temperature control, alarms and other user-oriented features for effective clinical workflow.

Infant Warmer KIW-A100
Infant Warmer KIW-A100

Control System : Microprocessor based temperature control system

Control Modes : Preheat, Manual and Skin-temp mode

Manual : Heater output : 0-100%, 10% increments

Phototherapy Unit

Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.

LED Phototherapy System KPT-A100

LED Phototherapy System KPT-A100

Light Source : 8 Blue LED lights

Wavelength : 450 to 475nm

LED Lamp-life : 1,00,000 hours

Defibrillator

Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.

Defibrillator Monitor KDM-A100

Defibrillator Monitor KDM-A100

Display : 7-inch screen

Waveform : Biphasic

Manual with Sync mode : 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules

Automated External Defibrillator KED-A100
Automated External Defibrillator KED-A100

Waveform : Biphasic

Energy Sequence : 150 J, 200 J

Analysis Time : 9 seconds

Ventilator

Acmed Equipment presents a wide range of pneumatically driven and electronically controlled ventilators that assist the breathing of adults and paediatric patients alike. Acmed Equipment Ventilators feature configurable loops and trends, invasive and non-invasive ventilation, adult and paediatric ventilation, high-flow oxygen therapy. They are applicable in hospitals, clinics, private practices and ambulances.

Intensive Care Ventilator KIV-A102
Intensive Care Ventilator KIV-A102

Tidal Volume : 10 ml ~ 300 ml

Standard Ventilation Mode : CMV, IMV, CPAP, Manual

Application : Pediatric

Intensive-Care Ventilator KIV-A200

Intensive-Care Ventilator KIV-A200

Tidal Volume : 20 ml ─ 2500 ml

Configurations : Trolley or Ceiling Pendant

Respiratory Rate : 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) </br> 4 bpm ─ 100 bpm ( VCV/PCV/PRVC)

Transport Ventilator KTV-A100

Transport Ventilator KTV-A100

Tidal Volume : 0 ml – 1500 ml

Gas Supply : O<sub>2</sub>, 0.28 to 0.6 MPa

Ventilation Modes : A/C, SIMV, SPONT, Manual, VCV+SIGH

Intensive Care Ventilator KIV-A101
Intensive Care Ventilator KIV-A101

Tidal Volume : 20 ml ~ 500 ml

Standard Ventilation Mode : VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH

Application : Adult/ Pediatric Invasive

Syringe Pump

Acmed Equipment offers a wide selection for Syringe Pump. Our Syringe pump systems are programmed with memory based on safety limits of drugs to deliver intermittent infusion for a specific duration according to associated safety and performance standards.

Syringe pump KSP-A100
Syringe pump KSP-A100

KVO Rate : 0.1 – 5ml/h (steps : 0.1ml/h)

Injection Compliance : Adaptable for 5 syringe sizes

Preset Volume Range : 0.1 ml – 1999.9 ml

Syringe pump KSP–A200

Syringe pump KSP–A200

Channel : Single channel infusion

Volume (VTBI) : 0 ml – 9999 ml

Injection Compliance : Adaptable for 6 syringe sizes

Syringe pump KSP–B100

Syringe pump KSP–B100

Channel : Dual channel infusion

Volume (VTBI) : 0.1 ml – 1999.9 ml

Injection Compliance : Adaptable for 10 syringe sizes

Blood and Infusion Warmer

Acmed Equipment offers a wide selection for Blood or Infusion warmer. Our infusion warmers are designed for leak-proof optimized warming with self-monitored temperature test and alarms as per associated safety and performance standards.

Blood and Infusion Warmer KBIW-A100
Blood and Infusion Warmer KBIW-A100

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 0.5°C

Warm-up Time : < 45 s (20°C to 36°C)

Blood and Infusion Warmer KBIW-A200
Blood and Infusion Warmer KBIW-A200

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 1.0°C

Warm-up Time : < 45 s (20°C to 36°C)

Resuscitator

Resuscitator KRE-A101

Resuscitator KRE-A101

Type : Pediatric

Stroke volume : 350 ml

Resuscitator volume : 680 ml

Resuscitator KRE-A102

Resuscitator KRE-A102

Type : Neonatal

Stroke volume : 150 ml

Resuscitator volume : 250 ml

Resuscitator KRE-A100
Resuscitator KRE-A100

Type : Adult

Stroke volume : 800 ml

Resuscitator volume : 1630 ml