Automated External Defibrillator KED-A100

Automated External Defibrillator KED-A100 is a biphasic portable semi-automated public access defibrillation device. System incorporates advanced cardiac life-support features which include step-by-step voice instructions from pad placement to shock delivery with clear visual real-time guidance indicators as well as electrode position analysis for safe and quick treatment aid during cardiac emergency suitable to use for on-the-spot responders with or without training.

21 Reviews
Waveform Biphasic
Energy Sequence 150 J, 200 J
Analysis Time 9 seconds
Audio Indications 20 distinct voice instructions
Charge Time 8 seconds for 150 J
10 seconds for 200 J
Capacity 100 discharges (200 J)
120 discharges (150 J)
Rhythm Analysis Time Less than 30 secs for new battery
Less than 35 secs after 6 shock discharge
Less than 25 secs at initial switch-on
Visual Indications LED flash light indicator
Control Keys Shock and On/Off keys
Energy Accuracy ± 15 % tolerance (25 Ω to 175 Ω)
Impedance Range 20 Ω to 200 Ω
Battery Non-rechargeable (12V DC)
Operating Temperature 0 °C to 40 °C
Operating Humidity 30 % to 95 %
Dimensions 303 x 216 x 89 mm
Weight 2 Kgs

Simple 3-step defibrillation process
Dual switch-press control
Max. discharge energy up to 200 J
Up to 20 distinct voice prompts
Lock-out protection facility
LED visual indicators

Used in various mass transit locations like Airports, Train stations, high traffic public places or outdoor activity parks, gyms, arenas, community centers as well as in public events to handle sudden cardiac emergency situations.

Buy Now: Automated External Defibrillator KED-A100

Related To Defibrillator

Defibrillator Monitor KDM-A100

Infant Incubator

Infant Incubator is used in neonatal care to regulate temperature and humidity conditions inorder to maintain a controlled environment for neonates. Acmed Equipment Infant Incubator range features accurate temperature and humidity monitoring and regulation, accessible outer shell with easy-to-clean surfaces, spacious adjustable baby bed.

Infant Incubator KII-A101

Infant Incubator KII-A101

Control System : Air-temp control & Skin-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A102

Infant Incubator KII-A102

Control System : Air-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C

Infant Incubator KII-A100
Infant Incubator KII-A100

Control System : Air-temp control, Skin-temp control & Humidity control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Warmer

Infant Warmer is an essential equipment in neonatal care to regulate radiant temperature, often used in maternity wards for newborn babies to provide them with controlled weaning temperature according to medicals standards and practice. Acmed Equipment Infant Warmer range provides a wide range with bed tilt, sensor-based temperature control, alarms and other user-oriented features for effective clinical workflow.

Infant Warmer KIW-A100
Infant Warmer KIW-A100

Control System : Microprocessor based temperature control system

Control Modes : Preheat, Manual and Skin-temp mode

Manual : Heater output : 0-100%, 10% increments

Phototherapy Unit

Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.

LED Phototherapy System KPT-A100

LED Phototherapy System KPT-A100

Light Source : 8 Blue LED lights

Wavelength : 450 to 475nm

LED Lamp-life : 1,00,000 hours

Infusion Pump

Acmed Equipment offers a wide range of superior quality portable and mini-sized Infusion pumps, suited for a wide range of applications in hospitals wards and clinics. Infusion pumps are medical devices capable of delivering a controlled dosage of fluidized drugs, enteral nutrition into a patient's circulatory system.

Infusion Pump KIP–A100

Infusion Pump KIP–A100

Channel : Single channel infusion

Volume (VTBI) : 1 ml ~ 9999.9 ml ( 0.1 ml increment)

Accuracy : Flow rate: ≤ ± 3 % </br> Mechanical: ≤ ± 2 %

Infusion Pump KIP–A101
Infusion Pump KIP–A101

Channel : Single channel infusion

Infusion Volume : 0 ml ~ 9999 ml ( 0.1ml increment)

Infusion Rate : 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)

Ventilator

Acmed Equipment presents a wide range of pneumatically driven and electronically controlled ventilators that assist the breathing of adults and paediatric patients alike. Acmed Equipment Ventilators feature configurable loops and trends, invasive and non-invasive ventilation, adult and paediatric ventilation, high-flow oxygen therapy. They are applicable in hospitals, clinics, private practices and ambulances.

Transport Ventilator KTV-A100
Transport Ventilator KTV-A100

Tidal Volume : 0 ml – 1500 ml

Gas Supply : O<sub>2</sub>, 0.28 to 0.6 MPa

Ventilation Modes : A/C, SIMV, SPONT, Manual, VCV+SIGH

Intensive Care Ventilator KIV-A101

Intensive Care Ventilator KIV-A101

Tidal Volume : 20 ml ~ 500 ml

Standard Ventilation Mode : VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH

Application : Adult/ Pediatric Invasive

Intensive Care Ventilator KIV-A102

Intensive Care Ventilator KIV-A102

Tidal Volume : 10 ml ~ 300 ml

Standard Ventilation Mode : CMV, IMV, CPAP, Manual

Application : Pediatric

Intensive-Care Ventilator KIV-A200
Intensive-Care Ventilator KIV-A200

Tidal Volume : 20 ml ─ 2500 ml

Configurations : Trolley or Ceiling Pendant

Respiratory Rate : 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) </br> 4 bpm ─ 100 bpm ( VCV/PCV/PRVC)

Syringe Pump

Acmed Equipment offers a wide selection for Syringe Pump. Our Syringe pump systems are programmed with memory based on safety limits of drugs to deliver intermittent infusion for a specific duration according to associated safety and performance standards.

Syringe pump KSP–B100
Syringe pump KSP–B100

Channel : Dual channel infusion

Volume (VTBI) : 0.1 ml – 1999.9 ml

Injection Compliance : Adaptable for 10 syringe sizes

Syringe pump KSP-A100

Syringe pump KSP-A100

KVO Rate : 0.1 – 5ml/h (steps : 0.1ml/h)

Injection Compliance : Adaptable for 5 syringe sizes

Preset Volume Range : 0.1 ml – 1999.9 ml

Syringe pump KSP–A200

Syringe pump KSP–A200

Channel : Single channel infusion

Volume (VTBI) : 0 ml – 9999 ml

Injection Compliance : Adaptable for 6 syringe sizes

Blood and Infusion Warmer

Acmed Equipment offers a wide selection for Blood or Infusion warmer. Our infusion warmers are designed for leak-proof optimized warming with self-monitored temperature test and alarms as per associated safety and performance standards.

Blood and Infusion Warmer KBIW-A200
Blood and Infusion Warmer KBIW-A200

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 1.0°C

Warm-up Time : < 45 s (20°C to 36°C)

Blood and Infusion Warmer KBIW-A100
Blood and Infusion Warmer KBIW-A100

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 0.5°C

Warm-up Time : < 45 s (20°C to 36°C)

Resuscitator

Resuscitator KRE-A102

Resuscitator KRE-A102

Type : Neonatal

Stroke volume : 150 ml

Resuscitator volume : 250 ml

Resuscitator KRE-A101

Resuscitator KRE-A101

Type : Pediatric

Stroke volume : 350 ml

Resuscitator volume : 680 ml

Resuscitator KRE-A100
Resuscitator KRE-A100

Type : Adult

Stroke volume : 800 ml

Resuscitator volume : 1630 ml