Intensive-Care Ventilator KIV-A200

Intensive-Care Ventilator KIV-A100 is a high performance, closed-loop controlled, pneumatically-driven critical care ventilator with multiple ventilation modes. System features high resolution detachable touch screen with navigation knob to view monitored parameters, pulmonary mechanics waveform, lung volumes, flow-volume loops and three-level audio-visual alarm system with 360-degree panoramic alert light.

21 Reviews
Tidal Volume 20 ml ─ 2500 ml
Configurations Trolley or Ceiling Pendant
Respiratory Rate 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV)
4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
Psupport 0 kPa ─ 6 kPa
Pcontrol 0.5 kPa ─ 6 kPa
Pulmonary Mechanics Waveform 3
Loops 2
Standard Ventilation Modes VCV (A/C)
PCV (A/C)
SIMV (VCV)
SIMV(PCV)
SIMV (PRVC)
SPONT/CPAP
NIV/CPAP
NIV/PCV
BIVENT
Combined Ventilation Modes SPONT+PS
SIMV(VCV)+ PS
SIMV(PCV)+PS
SIMS(PRVC)+PS
BIVENT+PS
VCV+SIGH
NIV/CPAP+PS
Inspiration Time 0.1 s ─ 12 s
Inspiratory Pause Time 0 s ─ 4 s
FiO2 Range 21% ─ 100%
Trigger Sensitivity Pressure : - 2 kPa to 0 kPa (above PEEP)
Flow : 0.5 LPM ─ 20 LPM (base flow)
PEEP 0 kPa ─ 5 kPa
Suction < 2 min
Nebulizer 30 mins
Pressure Values Pplat / Ppeak / Pmean / PEEP
Volume / Flow values VTI / VTE / MV / MVspont
Time Values Ftotal / Fspont / I : E
Oxygen Monitoring Without O2 sensor ( O2 sensor optional )
Gas Supply O2, Air (0.28 MPa – 6 MPa)
Real-time Curves Pressure-Time
Flow-Time
Volume-Time
Pressure-Volume loop
Flow-Volume loop
Alarm Upper and Lower limits : MV, Paw, PEEP, Airway Pressure continuous high, VTE, Fspont high
Other Conditions : Tapnea, ,Power Fail, Nebulizer, Battery low, Battery exhausted, Air supply failure, O2 supply failure, Air and O2 supply failure, Fan block, Pipe block, Circuit disconnected
Display 12.1” TFT LCD touch screen
Internal Battery > 1 hour
Maximum Security Pressure ≤ 8 kPa
Compliance ≤ 4 ml / 100 Pa
Noise ≤ 65 dB (A)
Communication RS232, VGA, Nurse Call
Operational Temperature 5 °C to 40 °C
Relative Humidity ≤ 90 % (non-condensing)
Atmospheric Pressure 50 kPa – 106 kPa
Power Supply 110 V – 240 V (50 Hz / 60 Hz), 65 VA
Dimensions 328 x 410 x 410 mm
Weight 20 Kgs

Pneumatic-driven Flow
Multiple Ventilation modes with BIVENT and PRVC Modes
Invasive and Non-invasive Modes
Flexible Configuration
15 Display Parameters
Alarm Recording Feature
Lung mechanics function monitoring

Used in operating rooms, surgical care wards, intensive care unit, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.

Buy Now: Intensive-Care Ventilator KIV-A200

Related To Ventilator

Transport Ventilator KTV-A100

Intensive Care Ventilator KIV-A101

Intensive Care Ventilator KIV-A102

Infant Incubator

Infant Incubator is used in neonatal care to regulate temperature and humidity conditions inorder to maintain a controlled environment for neonates. Acmed Equipment Infant Incubator range features accurate temperature and humidity monitoring and regulation, accessible outer shell with easy-to-clean surfaces, spacious adjustable baby bed.

Infant Incubator KII-A102

Infant Incubator KII-A102

Control System : Air-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C

Infant Incubator KII-A101

Infant Incubator KII-A101

Control System : Air-temp control & Skin-temp control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A100
Infant Incubator KII-A100

Control System : Air-temp control, Skin-temp control & Humidity control

Display : LED display

Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Warmer

Infant Warmer is an essential equipment in neonatal care to regulate radiant temperature, often used in maternity wards for newborn babies to provide them with controlled weaning temperature according to medicals standards and practice. Acmed Equipment Infant Warmer range provides a wide range with bed tilt, sensor-based temperature control, alarms and other user-oriented features for effective clinical workflow.

Infant Warmer KIW-A100
Infant Warmer KIW-A100

Control System : Microprocessor based temperature control system

Control Modes : Preheat, Manual and Skin-temp mode

Manual : Heater output : 0-100%, 10% increments

Phototherapy Unit

Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.

LED Phototherapy System KPT-A100

LED Phototherapy System KPT-A100

Light Source : 8 Blue LED lights

Wavelength : 450 to 475nm

LED Lamp-life : 1,00,000 hours

Defibrillator

Phototherapy Unit is a light-based therapy assembly which is widely used for primary treatment of neonatal Hyperbilurubinaemia or Jaundice. Acmed Equipment offers a wide range of phototherapy units in various configurations and operational features to deliver better neonatal care solutions.

Defibrillator Monitor KDM-A100

Defibrillator Monitor KDM-A100

Display : 7-inch screen

Waveform : Biphasic

Manual with Sync mode : 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules

Automated External Defibrillator KED-A100
Automated External Defibrillator KED-A100

Waveform : Biphasic

Energy Sequence : 150 J, 200 J

Analysis Time : 9 seconds

Infusion Pump

Acmed Equipment offers a wide range of superior quality portable and mini-sized Infusion pumps, suited for a wide range of applications in hospitals wards and clinics. Infusion pumps are medical devices capable of delivering a controlled dosage of fluidized drugs, enteral nutrition into a patient's circulatory system.

Infusion Pump KIP–A101
Infusion Pump KIP–A101

Channel : Single channel infusion

Infusion Volume : 0 ml ~ 9999 ml ( 0.1ml increment)

Infusion Rate : 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)

Infusion Pump KIP–A100

Infusion Pump KIP–A100

Channel : Single channel infusion

Volume (VTBI) : 1 ml ~ 9999.9 ml ( 0.1 ml increment)

Accuracy : Flow rate: ≤ ± 3 % </br> Mechanical: ≤ ± 2 %

Syringe Pump

Acmed Equipment offers a wide selection for Syringe Pump. Our Syringe pump systems are programmed with memory based on safety limits of drugs to deliver intermittent infusion for a specific duration according to associated safety and performance standards.

Syringe pump KSP–A200

Syringe pump KSP–A200

Channel : Single channel infusion

Volume (VTBI) : 0 ml – 9999 ml

Injection Compliance : Adaptable for 6 syringe sizes

Syringe pump KSP–B100
Syringe pump KSP–B100

Channel : Dual channel infusion

Volume (VTBI) : 0.1 ml – 1999.9 ml

Injection Compliance : Adaptable for 10 syringe sizes

Syringe pump KSP-A100
Syringe pump KSP-A100

KVO Rate : 0.1 – 5ml/h (steps : 0.1ml/h)

Injection Compliance : Adaptable for 5 syringe sizes

Preset Volume Range : 0.1 ml – 1999.9 ml

Blood and Infusion Warmer

Acmed Equipment offers a wide selection for Blood or Infusion warmer. Our infusion warmers are designed for leak-proof optimized warming with self-monitored temperature test and alarms as per associated safety and performance standards.

Blood and Infusion Warmer KBIW-A200

Blood and Infusion Warmer KBIW-A200

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 1.0°C

Warm-up Time : < 45 s (20°C to 36°C)

Blood and Infusion Warmer KBIW-A100

Blood and Infusion Warmer KBIW-A100

Temperature Range : 37°C to 42°C

Temperature Accuracy : ± 0.5°C

Warm-up Time : < 45 s (20°C to 36°C)

Resuscitator

Resuscitator KRE-A100
Resuscitator KRE-A100

Type : Adult

Stroke volume : 800 ml

Resuscitator volume : 1630 ml

Resuscitator KRE-A101
Resuscitator KRE-A101

Type : Pediatric

Stroke volume : 350 ml

Resuscitator volume : 680 ml

Resuscitator KRE-A102

Resuscitator KRE-A102

Type : Neonatal

Stroke volume : 150 ml

Resuscitator volume : 250 ml